USAGE:
xchan-units-with-si.pl [opt] file
MAKE IT EASY:
ln -s
xchan-units-with-si.pl xchan-units
PURPOSE:
Extracts
time
and
measurement
columns
from
GWR files
of
type
A1*
A2*
G1*
(and
*.TSF ?)
and prints to
stdout.
For .GGP files
there is a sister script xggp.
Options that apply identically to xggp are indicated
by
a `+´-sign below.
|
V
OPTIONS:
-c
+
Prints
an
easily readable table of the channels.
-q
- Like -c, all in one row, no decorations.
-C
cset[,cset..] - units conversion presets:
cset = signal:factor e.g. G1-Sig:-776.0 See
remark
-u
- Do unit conversion (still incomplete)
OBS! The temperatures T1-Ext T2-Ext T3-Ext
are not
of conversion type TDVOhm; the header is wrong about this.
Available:
factors, He-lvl, SiDiodes-2 -3 -4, Pt100V,
TDOhm, TDVOhm
Some of these, especially the SiDiodes, are rather
sophisticated functions.
`factors´ are simple; they can be set once with the -C
option,
and they can be hard-wired.
-l
(letter l, not 1) Prints a long string with all labels.
Use
eval set labs \= \'`xchan-units
-l RAW_o054/A2111210.054`\'
to assign to a single set parameter, or
set labs = `xchan-units -l
RAW_o054/A2111210.054`
to assign to an array
-H c[,c...]
+ Prints the header of column c (integer number).
Each
c
may
be
a
range
c1..c2
-N c[,c...] Prints the
channel number for measurement named c.
-x c[,c...] + The
requested channel numbers to retrieve.
Each
c
may
be
a
range
c1..c2 See remark
- The
requested channel names ...; no ranges then!
-x H
+ Print number of
channels
-I #c[,#c...]
- Signal information for specified channel number.
-S c[,c...]
- Signal information for specified channel name.
Verbose mode, no data out.
prints CONVERSION #chn S-name Conversion Units
like CONVERSION 31 T2-Ext TDVOhm Celsius
upon xchan-units -S T2-Ext RAW_o054/A1121013.054
or xchan-units -I 31 RAW_o054/A1121013.054
-m m
+ Print
only each m'th line
-n r
+ The number of records for
output
[100000]
A
value
<
0
will suppress printing;
0
doesn't
work,
"Look
at that stupid pe-herl!"
(Jagger&Richards)
-s
s
-
Skip
s records
-l
l
-
Output
l records (same function as -n but different
logic
-
maybe useful after a differenciated change.
-v
- Verbose mode, helpul for debug.
-V
-
reduced
verbose.
Shows
selected
channels
and unit conversions.
Remarks:
-x - If any of the -x channel
numbers is beyond the actual range,
the previous column will be
doubled.
-C - We have avoided to hard-wire this
particular conversion
since the factor might change and since
we might
like to keep the Volt units but
convert the other channels.
If you want to hard-wire a
factor for a particular channel, read here.
EXAMPLES:
xchan-units -C G1-Sig:-776.0
-u -x 5..8 RAW_o054/A1091107.054 > tmp.dat
retrieves channels 5 6 7 8 and does unit conversion.
Unit conversion would be with a preset factor of 1
(since the measurement file provides no information on factors for
these particular channels).
However, for channel 5 = G1-Sig the calibration factor is imposed.
Result from example
2009 11 07 00 00 00
-278.73291440
-0.08514400 0.00000000
-0.00030520
2009 11 07 00 01 00
-285.36375680 -0.08575440
-0.00030520 -0.00030520
2009 11 07 00 02 00
-246.05221760 -0.08361820
-0.00030520 0.00000000
2009 11 07 00 03 00
-384.35303280
-0.07629390
0.00000000 0.00030520
2009 11 07 00 04 00
-416.32322400
-0.06896970
0.00000000 0.00000000
2009 11 07 00 05 00
-363.75000000
-0.07263180 0.00000000
-0.00030520
...
12345678901234567890123456789012345678901234567890123456789012345678901234567890
1
2
3
4
5
6
7 8
Convert to mc-binary file
using
tslist
tmp.dat -A -g'(I4,5I3,f15.0)' -k3 -F1p,e18.10 -C3 -O`label
GRAV,VALnms2` file.mc -I
tslist tmp.dat -A
-g'(I4,5I3,t35,f15.0)' -k3 -F1p,e18.10 -C3 -O`label
MODE,VALnms2` file.mc -I
...
xchan-units -V -x 32..34 -n -1
RAW_o054/A1100301.054
SELECTION REQUESTED: 32 33 34
SELECTION GRANTED: 32 33 34
CONVERSION 32 T2-Ext TDVOhm Celsius
CONVERSION 33 T3-Ext TDVOhm Celsius
CONVERSION 34 Temp-G1 TDVOhm Celsius
xchan-units -H 32..34 -n -1
RAW_o054/A1100301.054
32:T2-Ext 33:T3-Ext
34:Temp-G1
xchan-units -x H RAW_o054/A1100301.054
48
xchan-units -V -x 48,49 -n -1
RAW_o054/A1100301.054
SELECTION REQUESTED: 48 49
Channel 49 not in file
SELECTION
GRANTED: 48 48
CONVERSION 48 RelHum2
factor,1.0 %
CONVERSION 48 RelHum2
factor,1.0 %
xchan-units -V -x 1..48 -n -1
RAW_o054/A1100301.054 | m
SELECTION REQUESTED: 1 2 3 4
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
SELECTION GRANTED: 1 2 3 4 5 6 7 8 9 10 11 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
36 37 38 39 40 41 42 43 44 45 46 47 48
CONVERSION 1 LHe-Lvl GEPLHe19
%
CONVERSION 2 AGnd factor,1.0 Volts
CONVERSION 3 AD-1 factor,1.0 Volts
CONVERSION 4 AD-2 factor,1.0 Volts
CONVERSION 5 G1-Sig factor,1.0 nm/sec2
CONVERSION 6 G1-Mode factor,1.0 Volts
CONVERSION 7 G2-Sig factor,1.0 nm/sec2
CONVERSION 8 G2-Mode factor,1.0 Volts
CONVERSION 9 Dewr-P PSI_1_1 PSI
CONVERSION 10 GBal-1 factor,1.0 nm/sec2
CONVERSION 11 TX-Pwr POWERV %Power
CONVERSION 12 TX-Bal factor,1.0 Volts
CONVERSION 13 NeckT-1 SiDiode-3 Kelvin
CONVERSION 14 NeckT-2 SiDiode-3 Kelvin
CONVERSION 15 BelyT-3 SiDiode-3 Kelvin
CONVERSION 16 BodyT-4 SiDiode-4 Kelvin
CONVERSION 17 LHeLvl GEPLHe19 %
CONVERSION 18 GBal-2 factor,1.0 nm/sec2
CONVERSION 19 TY-Pwr POWERV %Power
CONVERSION 20 TY-Bal factor,1.0 Volts
CONVERSION 21 Tmp-Bal factor,1.0 Volts
CONVERSION 22 HtrCrnt POWERV %Power
CONVERSION 23 Temp-6K factor,1.0 Volts
CONVERSION 24 Temp-77 factor,1.0 Volts
CONVERSION 25 FB-Mod factor,1.0 Volts
CONVERSION 26 P1GasCl PSI-3000 PSI
CONVERSION 27 P2GasRg PSI-500 PSI
CONVERSION 28 P3CmpHi PSI-500 PSI
CONVERSION 29 P4CmpLo PSI-500 PSI
CONVERSION 30 P5CmpBl PSI-500 PSI
CONVERSION 31 T1-Ext TDVOhm Celsius
CONVERSION 32 T2-Ext TDVOhm Celsius
CONVERSION 33 T3-Ext TDVOhm Celsius
CONVERSION 34 Temp-G1 TDVOhm Celsius
CONVERSION 35 Temp-G2 TDVOhm Celsius
CONVERSION 36 Temp-TX TDVOhm Celsius
CONVERSION 37 Temp-TY TDVOhm Celsius
CONVERSION 38 Temp-TE TDVOhm Celsius
CONVERSION 39 Temp-AX TDVOhm Celsius
CONVERSION 40 Temp-CH TDVOhm Celsius
CONVERSION 41 Temp-Gt PT100V_K Kelvin
CONVERSION 42 Dwr-Htr factor,20.0 mA
CONVERSION 43 Comp-DC factor,1.0 Volts
CONVERSION 44 CH-DC factor,1.0 Volts
CONVERSION 45 Tmpr1 factor,1.0 Celsius
CONVERSION 46 Tmpr2 factor,1.0 Celsius
CONVERSION 47 RelHum1 factor,1.0 %
CONVERSION 48 RelHum2 factor,1.0 %
xchan-units
-N Dwr-Htr,Temp-Gt RAW_o054/A1110101.054
41 Temp-Gt
42 Dwr-Htr
xchan-units -N
Dwr-Htr,Temp-Gt RAW_o054/A1120101.054
40 Temp-Gt
41 Dwr-Htr
ADDING
A FACTOR CONVERSION
In ~/TD/xchan-units
, a perl script, find the lines below and add a factor scheme
like the existing one for Dwr-Htr.
Note: The channel symbol is the one we convert to when GWR has
provided one that we don't like
(they called it Dwr_Htr and our software gets upset at
underscores; search for Dwr_Htr in the script.)
%conv
= ( "T1-Ext" => "TDVOhm",
"T2-Ext" => "TDVOhm",
"T3-Ext" => "TDVOhm",
"Temp-G1" => "TDVOhm",
"Temp-G2" => "TDVOhm",
"Temp-TX" => "TDVOhm",
"Temp-TY" => "TDVOhm",
"Temp-TE" => "TDVOhm",
"Temp-AX" => "TDVOhm",
"Temp-CH" => "TDVOhm",
"Dwr-Htr" => "factor,0.02"
);
%units =
( "T1-Ext" => "Celsius",
"T2-Ext" => "Celsius",
"T3-Ext" => "Celsius",
"Temp-G1" => "Celsius",
"Temp-G2" => "Celsius",
"Temp-TX" => "Celsius",
"Temp-TY" => "Celsius",
"Temp-TE" => "Celsius",
"Temp-AX" => "Celsius",
"Temp-CH" => "Celsius",
"Dwr-Htr" => "mA"
);
.bye